Water Cooling Condensing Unit for Cold Room

Condensation Forms: Air-Cooled
Refrigerant: R22
Type: Steam Condenser
Structural Form: Vertical
Heat Transfer Mode: Regenerative
Form: Fixed Tube-Sheet

Contact Supplier

Diamond Member Since 2013

Suppliers with verified business licenses

Rating: 5.0/5
Manufacturer/Factory & Trading Company

Basic Info.

Model NO.
water cooling /air cooling
Application Field
Industrial Cooling
Certification
CCC
Condition
New
Transport Package
Carton/Pallte
Specification
CCC
Trademark
brillant
Origin
Zhejiang. China(Mainland)

Product Description


Technical data: 
compressor,sub-semi-closed and closed are the international and domestic famous barnd product

with high efficiency,low noise,low wear and long life characteristics as the main part of the unit;ourcompany product good quality condenser,supporting high-quality refrigeration parts,precision design,painstakingly created by the professional and technical personnel,combined with advanced production and test equipment,so that the entire unit's performance is more stable,reliable,efficient and energy saving.

Safety protection:
1 standard with the unit are equipped with high and low pressure control switch, when operating conditions exceed the design conditions or equipment failure,high and low pressure control switch action to protect the compressor and the whole system's security.2 compressor built-in thermal protection device,when the compressor is running under normal circumstances,or motor current load exceeds the setting valve of the built-in protection. It will automatically cut off thepower to prevent to prevent motor coil from high temprerature result motor burned.3 safety valve(fusible plug) to ensure the normal operation of the equipment in a safe accidents.
Application:
The products are widely used: refrigerated,central air conditioning, petrochemical,pharmaceutical industry,power industry,plant workshops cooling ,factory production of agricultural products, cold chain logistics and other places.

Special Note:
1 water-cooled units,when the ourdoor temperature is low, causing the device with water frozen to cope with the water
system of the eqiupment(units)as insulation to prevent equipment damage due to frozen, The rpw within the storage in the unit when not in use shall be to ensure that the units in the next time you use the normal time to run.clear device

2 unit commissioning, maintenance and repair should be professionals, non-professional non-operation, to prevent damage to equipment and serious security incidents.

Size  of installation :

Water Cooling Condensing Unit for Cold Room
Water Cooling Condensing Unit for Cold RoomThe Technical Parameter of BITZER Semi-hermetic Type Wind Cooling Units:
(the middle-high temperature type)

Project Horsepower Ref.Capacity Compressor power The wind condenser parameter In and out of the tube diameter
Model Heat exchange area Total volume air Motor Power Air suction Outlet pipe

HP R22(W) KW
m³/h n*W mm mm
2HC2.2/FH18H 2 3380 1.62 18 3400 1*180 16 10
2FC3.2/FH28H 3 4820 2.31 28 4400 2*140 16 10
2DC3.2/FH33H 3 6780 2.98 33 4400 2*140 22 12
2CC4.2/FH41H 4 8350 3.67 40 6800 2*180 22 12
4FC5.2/FH50H 5 9640 4.12 50 6800 2*180 22 12
4EC6.2/FH60H 6 11850 5.12 60 6800 2*180 28 12
4DC7.2/FH72H 7 14480 6.14 72 8800 4*140 28 16
4CC9.2/FH80H 9 17500 7.5 80 13600 4*180 28 16
4VCS10.2/FH100H 10 19200 7.43 100 13600 4*180 28 16
4TCS12.2/FH120H 12 23150 9.13 120 13600 4*180 35 16
4PCS15.2/FH140H 15 27700 10.45 140 19200 4*250 42 16
4NCS20.2/FH180H 20 32150 12.6 180 19200 4*250 42 22
4J22.2/FV180H 22 36200 13.9 180 21600 2*780 42 22
4H25.2/FV200H 25 41950 16.1 200 21600 2*780 54 22
4G30.2/FV240H 30 48100 19.04 250 26100 3*600 54 22
6H35.2/FV300H 35 63000 24.2 300 32400 6*780 54 22
6G40.2/FV350H 40 72200 28.6 350 36600 3*800 54 28
6F50.2/FV400H 50 85700 35.5 400 36600 3*800 54 28
8GC60.2/FV450H 60 111200 43.4 450 48800 4*800 76 35
8FC70.2/FW560H 70 121200 53.9 560 73200 6*850 76 35
The Technical Parameter of BITZER Semi-hermetic Type Wind Cooling Condenser
(the middle-low temperature type)


Project Horsepower Ref.Capacity Compressor power The wind condenser parameter In and out of the tube diameter
Model Heat exchange area Total volume air Motor Power Air suction Outlet pipe

HP R22(W) KW
m³/h n*W mm mm
2FC2.2/FH18 2 3100 1.89  18 3400 1*180 16 10
2CC3.2/FH28 3 5230 3.04  26 4400 2*140 22 10
4FC3.2/FH33 3 5950 3.42  33 4400 2*140 22 12
4EC4.2/FH41 4 7360 4.24  41 6800 2*180 28 12
4DC5.2/FH50 5 9020 5.09  50 6800 2*180 28 12
4VCS6.2/FH60 6 12490 6.34  58 6800 2*180 28 12
4TCS8.2/FH72 8 15250 7.73  72 8800 4*140 35 16
4PCS10.2/FH80 10 17700 8.93  80 13600 4*180 35 16
4NCS12.2/FH100 12 20850 10.43  100 13600 4*180 35 16
4H15.2/FH120 15 26800 14.13  120 13600 4*180 42 16
4G20.2/FH160 20 30950 16.65  150 19200 4*250 54 22
6H25.2/FV200 25 40250 21.20  200 21600 2*780 54 22
6G30.2/FV240 30 46500 25.00  250 24100 3*600 54 22
6F40.2/FV300 40 55600 30.40  300 32400 3*780 54 22
Water Cooling Condensing Unit for Cold Room 1.The Technical Parameter of BITZER Semi-hermetic Type Water Cooling Condenser
Project Horsepower Ref.Capacity Compressor power The wind condenser parameter In and out of the tube diameter
Model Condenser model cooling water wolume in and out of the water tube diameter Air suction Outlet pipe

HP R22(W) KW m³/h mm mm
2FC2.2/RXWN003 2 3640 1.73  RXWN-003 2.20  G1 16 10
2CC3.2/RXWN003 3 6380 2.79  RXWN-003 2.20  G1 22 10
4FC3.2/RXWN003 3 7140 3.16  RXWN-003 2.20  G1 22 12
4EC4.2/RXWN005 4 8880 3.92  RXWN-005 3.00  G1½ 28 12
4DC5.2/RXWN005 5 10800 4.70  RXWN-005 3.00  G1½ 28 12
4VCS6.2/RXWN008 6 14620 5.83  RXWN-008 4.30  G1½ 28 12
4TCS8.2/RXWN008 8 17840 7.11  RXWN-008 4.30  G1½ 35 16
4PCS10.2/RXWN010 10 20700 8.25  RXWN-010 5.20  G2 35 16
4NCS12.2/RXWN015 12 24150 9.66  RXWN-015 8.40  G2 35 16
4H15.2/RXWN015 15 30500 12.56  RXWN-015 8.40  G2 42 16
4G20.2/RXWN020 20 35100 14.60  RXWN-020 11.00  G2 54 22
6H25.2/RXWN025 25 45850 18.84  RXWN-025 13.40  G2 54 22
6G30.2/RXWN030 30 52700 21.90  RXWN-030 16.50  G2 54 22
6F40.2/RXWN040 40 62600 27.00  RXWN-040 21.80  G2½ 54 22

2.The Technical Parameter of BITZER Semi-hermetic Type Water Cooling Condenser
(the middle-high temperature type)
Project Horsepower Ref.Capacity Compressor power The wind condenser parameter In and out of the tube diameter
Model Condenser model cooling water wolume in and out of the water tube diameter Air suction Outlet pipe

HP R22(W) KW m³/h mm mm
2HC2.2/RXWN003H 2 3910 1.40  RXWN-003 2.20  G1 16 10
2FC3.2/RXWN003H 3 5590 2.00  RXWN-003 2.20  G1 16 10
2DC3.2/RXWN005H 3 7980 2.69  RXWN-005 3.00  G1½ 22 12
2CC4.2/RXWN005H 4 9890 3.31  RXWN-005 3.00  G1½ 22 12
4FC5.2/RXWN005H 5 11230 3.66  RXWN-005 3.00  G1½ 22 12
4EC6.2/RXWN008H 6 13860 4.56  RXWN-008 4.30  G1½ 28 12
4DC7.2/RXWN008H 7 16830 5.40  RXWN-008 4.30  G1½ 28 16
4CC9.2/RXWN010H 9 20250 6.62  RXWN-010 5.20  G2 28 16
4VCS10.2/RXWN010H 10 22250 6.61  RXWN-010 5.20  G2 28 16
4TCS12.2/RXWN015H 12 26800 8.09  RXWN-015 8.40  G2 35 16
4PCS15.2/RXWN020H 15 31950 9.35  RXWN-020 11.00  G2 42 16
4NCS20.2/RXWN025H 20 37000 11.34  RXWN-025 13.40  G2 42 22
4J22.2/RXWN025H 22 41000 12.24  RXWN-025 13.40  G2 42 22
4H25.2/RXWN030H 25 47150 14.17  RXWN-030 16.50  G2 54 22
4G30.2/RXWN035H 30 54000 16.67  RXWN-035 19.50  G2½ 54 22
6H35.2/RXWN040H 35 70800 21.30  RXWN-040 21.80  G2½ 54 22
6G40.2/RXWN050H 40 81100 25.00  RXWN-050 27.30  G3 54 28
6F50.2/RXWN060H 50 95900 31.30  RXWN-060 31.80  G3 54 28
8GC60.2/RXWN070H 60 125900 38.70  RXWN-070 38.70  G3 76 35
8FC70.2/RXWN080H 70 138500 48.30  RXWN-080 43.00  G3 76 35

Send your message to this supplier

*From:
*To:
avatar Miss Lucy
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

You Might Also Like

Contact Supplier

Diamond Member Since 2013

Suppliers with verified business licenses

Rating: 5.0/5
Manufacturer/Factory & Trading Company
Year of Establishment
2013-05-16
Management System Certification
ISO 9001, ISO 9000